Fix use-after-free issue in slot synchronization.

Author: Shlok Kyal <shlok.kyal.oss@gmail.com>
Reviewed-by: Daniel Gustafsson <daniel@yesql.se>
Reviewed-by: Amit Kapila <amit.kapila16@gmail.com>
Backpatch-through: 18, where it was introduced
Discussion: https://postgr.es/m/CANhcyEXMrcEdzj-RNGJam0nJHM4y+ttdWsgUCFmXciM7BNKc7A@mail.gmail.com
master
Amit Kapila 1 week ago
parent db9405493b
commit f2dbc83501
  1. 3
      src/backend/replication/logical/slotsync.c
  2. 3
      src/backend/replication/slotfuncs.c

@ -1476,7 +1476,6 @@ ReplSlotSyncWorkerMain(const void *startup_data, size_t startup_data_len)
*/
wrconn = walrcv_connect(PrimaryConnInfo, false, false, false,
app_name.data, &err);
pfree(app_name.data);
if (!wrconn)
ereport(ERROR,
@ -1484,6 +1483,8 @@ ReplSlotSyncWorkerMain(const void *startup_data, size_t startup_data_len)
errmsg("synchronization worker \"%s\" could not connect to the primary server: %s",
app_name.data, err));
pfree(app_name.data);
/*
* Register the disconnection callback.
*

@ -921,7 +921,6 @@ pg_sync_replication_slots(PG_FUNCTION_ARGS)
/* Connect to the primary server. */
wrconn = walrcv_connect(PrimaryConnInfo, false, false, false,
app_name.data, &err);
pfree(app_name.data);
if (!wrconn)
ereport(ERROR,
@ -929,6 +928,8 @@ pg_sync_replication_slots(PG_FUNCTION_ARGS)
errmsg("synchronization worker \"%s\" could not connect to the primary server: %s",
app_name.data, err));
pfree(app_name.data);
SyncReplicationSlots(wrconn);